NEC 2026 Article 120 Dwelling Load Calculator (New 2 VA/sq.ft. Standard)

Updated for the 2026 National Electrical Code reorganization relocating Article 220 into Article 120 and lowering general lighting demand from 3 VA/ftu00b2 to 2 VA/ftu00b2.

✓ Instant 4-Page PDF + Vector SVG ✓ Zero Account Required ✓ 100% Inspector Acceptance Guarantee
CALCULATING...
0%
💡 Avoid a $4,500+ 200A Service Upgrade — Pass Inspection Legally with EVEMS
Code authorities (CEC Rule 8-106(10) & NEC 625.42) exclude EV demand when controlled by a listed Energy Management System:

Download Complete 4-Page Permit PDF + Vector Schematic

Instant self-serve download + 30-Day Magic Edit Link (change address or numbers anytime free).

Single Permit Packet
$29 One-Time
  • ✓ Full 4-Page Official Calculation PDF
  • ✓ Vector Single-Line Diagram (SLD)
  • ✓ 30-Day Magic Link (unlimited edits)
No Subscription · 5-Pack
$79 / 5 Permits
  • ✓ $15.80 per permit packet
  • ✓ Credits never expire
  • ✓ Your Company Logo + License #
Contractor Pro Unlimited
$39 / month
  • ✓ Unlimited Branded Permit PDFs
  • ✓ Company Logo & License Header
  • ✓ Cancel anytime in 1 click
🛡️ 100% AHJ / HOA Acceptance Guarantee: Full refund within 30 days if rejected. 🔒 Stripe · Apple Pay & Credit Card
LIVE 4-PAGE PERMIT PACKET PREVIEW
Site:
DOC: CP-2026-PREVIEW
🔒 Official Code Schedule & Vector Schematic Locked
Unlock instant 4-page PDF download + 30-day self-service editing above.
Ln Description & Prescriptive Formula Code Ref Input Calculated

Worked Prescriptive Calculation Example: NEC 2026 Article 120 Dwelling Load Calculator (New 2 VA/sq.ft. Standard)

Below is a complete step-by-step mathematical schedule generated from standard nameplate ratings so municipal plan examiners, homeowners, and contractors can verify every code formula:

Line Step Description & Formula Code Reference Rating Calculated
1 General Lighting & Receptacles: 2,800 sq.ft. × 2 VA/sq.ft. NEC 2026 Art. 120(B)(1) 5,600 VA 5,600 VA
2 Small Appliance & Laundry Branch Circuits: 3 circuits × 1,500 VA NEC 2026 Art. 120(B)(2) 4,500 VA 4,500 VA
3 Fastened-in-Place Appliances (Range 12,000 + Dryer 5,000 + Water/Other 5,000 VA) NEC 2026 Art. 120(B)(3)-(4) 22,000 VA 22,000 VA
4 Optional General Demand Factor: 100% first 10,000 VA + 40% of remaining 22,100 VA NEC 2026 Art. 120 Demand 32,100 VA 18,840 VA
5 Largest Non-Coincident HVAC Load: Air-Conditioning / Heat Pump @ 100% NEC 2026 Art. 120(C) 4,800 VA 4,800 VA
6 Tesla Wall Connector Gen 3 (48A) — Continuous EVSE Load @ 125% Strict AHJ Mode NEC 625.41 / Continuous 11,520 VA 14,400 VA
7 Total Calculated Dwelling Demand (38,040 VA ÷ 240V = 158.5 Amps) NEC 2026 Art. 120 Total — 38,040 VA

Frequently Asked Permit & Inspection Questions

What changed in NEC 2026 Article 120 for residential load calculations?

The 2026 NEC relocated load calculation rules from Article 220 to Article 120 and reduced the general lighting and receptacle unit load for dwellings from 3 VA/ftu00b2 to 2 VA/ftu00b2 to reflect modern LED lighting efficiency.