Automated multi-dwelling demand calculation (100% largest unit + 65% second unit per Rule 8-202(3)) for basement apartments, laneway suites, and duplex permits.
Instant self-serve download + 30-Day Magic Edit Link (change address or numbers anytime free).
| Ln | Description & Prescriptive Formula | Code Ref | Input | Calculated |
|---|
Below is a complete step-by-step mathematical schedule generated from standard nameplate ratings so municipal plan examiners, homeowners, and contractors can verify every code formula:
| Line | Step Description & Formula | Code Reference | Rating | Calculated |
|---|---|---|---|---|
| 1 | Primary Dwelling Area (165.0 m²): 5,000 W first 90 m² + 1 × 1,000 W | CEC 8-110 & 8-200(1)(a)(i-ii) | 165.0 m² | 6,000 W |
| 2 | Electric Range: 6,000 W base + 40% of rating exceeding 12,000 W | CEC 8-200(1)(a)(iv) | 12,000 W | 6,000 W |
| 4 | Other Loads >1,500 W (Dryer 5,500 W + Fixed 4,500 W) @ 25% (Range provided) | CEC 8-200(1)(a)(vii) | 10,000 W | 2,500 W |
| 4B | Secondary Suite (80 m²): Unit Calc 12,125 W -> Multi-Unit 100% Largest (14,500 W) + 65% 2nd Unit (7,881 W) | CEC 8-200(2) & 8-202(3)(a) | 12,125 W | 7,881 W |
| 5 | Electric Space Heating (100% first 10 kW + 75% balance; interlocked w/ AC) | CEC 8-200(1)(a)(iii) & 62-118 | 12,000 W | 11,500 W |
| 6 | ChargePoint Home Flex (40A) — Monitored & Controlled by CSA-Listed EVEMS (0 W Service Demand) | CEC 8-106(10)/(11) & 8-500 | 9,600 W | 0 W |
| 7 | Total Calculated Service Demand — Greater of Item (a) 33,881 W or Min Floor (b) 24,000 W | CEC 8-200(1)(b) | Min Check | 33,881 W |
Each dwelling unit load is first calculated excluding space heating and air conditioning. Under Rule 8-202(3)(a), the combined feeder/service takes 100% of the unit with the heavier load plus 65% of the second unit, then adds heating/AC and EVSE loads.
On a 100A panel, two electric ranges plus heating frequently exceed 24,000 W unless gas appliances or load-management controls are utilized. Running the exact 8-200(2) schedule verifies whether 100A, 125A, or 200A is required.